10 22 13 Wire Mesh Partitions


10 22 13 Wire Mesh Partitions
by SecurityCaging.com

At SecurityCaging.com, we solve problems of storage, organization, safety, pilfering, restricted access, and more.
 

Our product delivers a strong deterrent to intrusion, is durable, and provides a high-end, professional appearance. SecurityCaging.com is always the right choice. When you don’t want to leave security to chance, rely on the reputation of International Vault, our parent company, with almost 4 decades of experience supplying modular vaults and physical security solutions to clients, worldwide.

10 22 13 – Wire Mesh Partitions

Master Format 1995 – 10605

Division 10 – Specialties

 

PRODUCTS

Materials

Metal post and framing materials listed below must contain within a minimum of 15% post-consumer recycled content and wire materials must contain a minimum of 50% post-industrial recycled content. Provide data identifying the percentage of recycled content for metal post and framing materials. Also, provide data identifying the percentage of recycled content for wire materials. 

  • Steel Shapes, Plates, & Bars
    • ASTM A36/A36M.
  • Cold-Formed Steel
    • AISI SG03-3.
  • Wire Mesh
    • Carbon steel wire, woven diamond mesh, intermediate crimped. 
  • Floor Sockets
    • Cast or forged steel or ductile iron, adjustable, approximately 64 mm 2-½ inches high. 

SecurityCaging.com provides all required LEED and recycled content of materials as required for approvals and submittals.  

Normal Duty Partitions

  • Wire Mesh
    • 10 gage wire, 38 mm 1-½ inch woven mesh OR 10 gage wire, 38 mm 2 inch welded mesh
  • Vertical Frames
    • 32 by 16mm 1-¼ by ⅝ inch cold-rolled C section channels or 32 by 16 by 3 mm 1-¼ by ⅝ by ⅛ inch channels. [Provide only C channels where frames are installed toe to toe without posts.]
  • Horizontal Frames
    • 25 by 16mm 1 by ⅝ inch channels. 
  • Center Reinforcing Bar
    • One 25 by 13 by 3 mm 1 by ½ by ⅛ inch channel with all wires woven through, or two 25 by 10 by 3 mm 1 by ⅜ by ⅛ inch channels bolted together with mesh in between.
  • Capping Bar
    • 56 by 25 by 3 mm 2-¼ by one by ⅛ inch channel or 50 by 6 mm 2 by ¼ inch flat bar.
  • 2.6 Corner Posts
    • Structural steel and angles, 32 by 32 by 3 mm 1-¼ by 1-¼ by ⅛ inch.
  • Line Posts
    • Unless otherwise indicated, provide partitions more than 3600 mm 12 feet high with flat bar line posts bolted between vertical frame channels. Size of posts must be as follows:
Partition Height (mm) Size of Posts (mm)
3600 to 4400 mm 44 by 7.9 mm or 50 by 6 mm
4400 to 5900 mm 63 by 7.9 mm 
5900 to 7100 mm  75 to 7.9 mm 
Partition Height (inches) Size of Posts (inches)
12 feet to 14 feet 8 inches 1-¾ by 5/16 inch or 2 by ¼ inch
14 feet 8 inches to 19 feet 8 inches 2-½ by 5/16 inch
19 feet 8 inches to 23 feet 8 inches 3 by 5/16 inch

 

  •  Hinged Doors 
    • Frames must be 32 by 13 by 3 mm 1-¼ by ½ by ⅛ inch channels with 32 by 3 mm 1-¼ by ⅛ inch flat bar cover on top and bottom rails and on hinge stile and a 35 by 20 by 3 mm 1-⅜ by ¾ by ⅛ inch angle riveted to the lock stile. Provide 1 ½ pairs of regular weight, wrought steel, non-removable pin, butt hinges riveted or welded to the door and the door opening frame for each door. 
  • Sheet Metal Base
    • Hot – or cold-rolled sheet steel, not lighter than 16 gage. 

SecurityCaging.com offers both 10-ga 1-1/2″ Woven Mesh and 10-ga 2″ Welded Mesh for Normal Duty Partition Applications. Read more about our mesh types here

Heavy Duty Partitions

  • Wire Mesh
    • 6 gage wire, 50 mm 2 inch mesh. 
  • Panel Frames
    • 38 by 20 by 3 mm 1-½ by ¾ by ⅛ inch steel channels.
  • Center Reinforcing Bar
    • One 38 by 20 by 3 mm 1-½ by ¾ by ⅛ inch channel with all wires woven through, or two 32 by 10 by 3 mm 1-¼ by ⅜ by ⅛ inch channels bolted together with mesh in between.
  • Capping Bar
    • Structural steel channel, 75 mm by 1.9 kg 3 inch by 4.1 pounds.
  • Corner Posts
    • Structural steel angles, 45 by 45 by 3 mm 1-¾ by 1-¾ by ⅛ inch.
  • Line Posts
    • Unless otherwise indicated, provide partitions with flat bar line posts bolted between vertical frame channels. Size of posts must be as follows:
Partition Height (mm) Size of Posts (mm)
2100 to 3600 mm 62 by 7.9 mm
3600 to 4800 mm 75 by 7.9 mm or 62 by 10 mm
4800 to 6000 mm 87 by 7.9 mm
Partition Height (inches) Size of Posts (inches)
7 feet to 12 feet 2-½ by 5/16 inch
12 feet to 16 feet 3 by 1/16 inch or 2-½ by ⅜ inch
16 feet to 20 feet 3-½ by 5/16 inch

 

  • Hinged Doors
    • Frames must be 38 by 20 by 3 mm 1-½ by ¾ by ⅛ inch channels with 38 by 3 mm 1-½ by ⅛ inch flat bar cover on top and bottom rails and on hinge stile and a 41 by 22 by 3 mm 1-⅝ by ⅞ by ⅛ inch angle riveted to the lock stile. Provide 1-½ pairs of heavyweight, wrought steel, non-removable pin, butt hinges riveted or welded to the door and the door opening frame for each door. 

SecurityCaging.com offers both 6-ga 2″ Woven Mesh and 6-ga 2″ Welded Mesh for Heavy Duty Partition Applications. Read more about our mesh types here

Sliding Doors

Frames must be 38 by 20 by 3 mm 1-½ by ¾ by 1/8 inch channels with 38 by 3 mm 1-½ by ⅛ inch flat bar cover all around. Provide two four-wheel, roller bearing hangers and steel box track for each door.

SecurityCaging.com offers custom sized slide and hinge door options. Read more about our door types here

Door Opening Frames

Provide frames the same size and shape as the vertical frames for the mesh panels.

Locks

Provide each door with a mortise type lock with a six-pin tumbler lock cylinder on the outside and a recessed knob on the inside. 

SecurityCaging.com offers alternate lock options. Read more on our Lock Option page.

Service Windows

Slide up type, mounted in standard mesh panel reinforced with channel tracks. Opening must be 600 mm wide by 450 mm high 24 inches wide by 15 inches high unless otherwise indicated. Provide two spring loaded latches, operable only from the inside, to lock window in open and closed positions. [Form shelf of 12 gage sheet steel, 300 mm deep by 625 mm wide 12 inches deep by 25 inches wide, unless otherwise indicated. ]

Fabrication

  • Standard Panels
    • Wire must be woven into diamond mesh, intermediate crimped, and securely clinched to frames. Joints must be mortised and tenoned. Wire must be continuous at center reinforcing bars, either woven through a single channel or bottled between two channels. Panel vertical frames must have [6 mm ¼ inch bolt holes 300 mm 12 inches o.c. for normal duty partitions] [10 mm3/8 inch bolt holes 450 mm 18 inches o.c. for heavy duty partitions].
  • Sheet Metal Base Panels
    • Upper portion must be as specified for standard panels, except that the wire must be clinched into the center reinforcing bar. Form sheet steel to fit between the panel frames and securely bolt to the frames. 
  • Doors [and Service Windows]
    • Construction must be similar to that specified for panels. Wire mesh must be the same as that used in the adjacent partition panels.
  • Finish
    • Thoroughly clean ferrous metal, treat with phosphate, and paint with [green] [black] [gray] enamel in the shop. 

EXECUTION

Installation

  • Wire Mesh Partitions
    • Install plumb, level, and true to line, within a tolerance of 3 mm in 3 m 1/8 inch in 10 feet or the height or run of the partition, if less than 3 meters 10 feet. Anchor floor sockets to the floor with expansion bolts. Bolt vertical frames and posts together with [6 mm bolts 300 mm o.c.1/4 inch bolts 12 inches o.c. for normal duty partitions] [10 mm bolts 450 mm o.c.3/8 inch bolts 18 inches o.c. for heavy duty partitions]. Secure top frames to a continuous capping bar with 6 mm 1/4 inch diameter U bolts not more than 650 mm 28 inches o.c.
  • Doors [and Service Windows]
    • Install in accordance with the manufacturers’ recommendations. Adjust as required so that doors [, windows,] and hardware operate freely and properly.
  • Bracing
    • Brace free standing partitions more than 6 meters 20 feet in length, at intervals not greater than 6 meters 20 feet [with a steel channel brace connected to the capping bar and anchored to the building wall or framing member] [with a structural steel I section or tube post welded to a 225 by 225 mm 9 by 9 inch steel base plate anchored to the floor with 4 expansion bolts] [or as indicated].
  • Touch-Up
    • Clean and paint scratches, abrasions, and other damage to shop painted surfaces to match the shop-applied finish. Repair minor surface rust areas. Clean and prime with rust inhibitive primer paint. Apply final paint to match shop-applied finishes.

For more information: https://www.wbdg.org/FFC/DOD/UFGS/UFGS%2010%2022%2013.pdf